MOTIONIQ IMAGING · ADVANCED SPINAL MOTION DIAGNOSTICS
Dynamic imaging to measure spinal motion, ligament integrity and instability. Objective testing for real impact: accurate, reliable, defensible.
OBJECTIVE TESTING FOR REAL IMPACT
Dynamic imaging to measure spinal motion, ligament integrity and instability. An FDA-cleared, motion-based technology that analyzes spinal movement frame by frame under controlled bending.
Quantifies abnormal spinal motion and instability.
Captures motion during controlled bending not seen on standard MRI or static X-rays.
Supports injury documentation, causation and case value.

VMA® REPORT EXAMPLES
| Level | Neutral | Flexion | Extension |
|---|---|---|---|
| C3/C4 | 0.4 | 1.1 | 0.9 |
| C4/C5 | 0.6 | 2.3 | 1.4 |
| C5/C6 | 0.5 | 3.1 | 1.8 |
| C6/C7 | 0.7 | 2.6 | 1.2 |
| Level | Max Trans. | Δ Views | Max Ang. (F/E) |
|---|---|---|---|
| L1/L2 | 1.2mm | 0.4mm | 8° / 6° |
| L2/L3 | 1.5mm | 0.6mm | 10° / 7° |
| L3/L4 | 2.1mm | 1.1mm | 12° / 9° |
| L4/L5 | 3.4mm | 2.0mm | 15° / 11° |
| L5/S1 | 2.8mm | 1.5mm | 13° / 10° |
OBJECTIVE TREATMENT RESPONSE
VMA quantifies treatment response by comparing segmental motion before and after intervention, giving clinicians and attorneys defensible evidence of efficacy that subjective pain scales cannot.
Sagittal Translation (Extension) at C5/C6
Returned to normal range
Following a 12-week targeted stabilization protocol, cervical translation at C5/C6 reduced from -3.1 mm (-22%) to -1.2 mm (-8%), moving the patient from a flagged excessive-motion threshold back within normal range. Static imaging showed no structural change across the same period.
VMA® captures dynamic fluoroscopic motion of the cervical spine through full flexion and extension, revealing segmental translation and rotation that static imaging can miss.
FROM MOTION TO MEDICAL EVIDENCE
Detailed, measurable data with clear visual analysis.
| Level | Neutral | Flexion | Extension |
|---|---|---|---|
| C3/C4 | -0.5 | -0.2 | -0.4 |
| C4/C5 | 0.3 | 1.1 | -1.5 |
| C5/C6 | -2.6 | -1.4 | -3.1 |
| C6/C7 | -1.4 | -1.0 | -1.0 |
Highlighted values indicate potential mal-alignment or excessive motion.
POWERED BY DRIVING FORCE
We bring Driving Force's FDA-cleared Vertebral Motion Analysis technology to practices and attorneys in San Antonio and surrounding areas, with fast scheduling and timely reports.
LEADERSHIP
Non-invasive outpatient testing. Direct-pay pricing with no LOP required.
© MotionIQ Imaging. VMA® is a registered trademark of its owner; MotionIQ Imaging is a Driving Force distributor.